LiveZilla Live Chat Software

APC SMART UPS (SMX), 1000VA, IEC(8), EXT BATT(0/10), SMART SLOT, LCD, 2U RACK/TWR, 3YR SMX1000I

product_image
  • Product Code :SMX1000I
  • Manufacturer P/N :SMX1000I
  • Manufacturer :APC
  • APC SMX1000I APC UPS
SCHNEIDER SMART-UPS X 1000VA RACK/TOWER LCD 230V
Quantity :
Price($) :
$1,384.53
Don't Pay: $1,825.00
Buy it now
Customer rating :
Total votes : 0
Add to wishlist Availability: Pre-Order [What this means?]

 

APC SCHNEIDER SMX1000I SMART-UPS X 1000VA RACK/TOWER LCD 230V

SMX1000I Features

EPO 
Attach the device to an Emergency Power Off (EPO) system so that power can be turned off in an emergency situation.
High online efficiency 
Reduces utlility costs, generates less heat.
Green mode 
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High frequency design 
Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
Energy meter 
Provides actual kilowatt hours of usage for energy conscious users.
Predictive replace battery date 
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Intuitive LCD interface 
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Auto recognition of external batteries 
UPS recognizes when external battery packs are attached and automatically adjusts runtime.
Multiple switched outlet groups 
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
Pure sine wave output on battery 
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Scalable runtime 
Allows additional run time to be quickly added as needed.
Cold-start capable 
Provides temporary battery power when the utility power is out.
Plug-and-Play external batteries 
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible 
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
SmartSlot 
Customize UPS capabilities with management cards.
Temperature-compensated battery charging 
Prolongs battery life by regulating the charge voltage according to battery temperature.

 

 

Smart-UPS Features & Benefits

Availability
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Manageability
Network manageable
Provides remote power management of the UPS over the network.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Serviceability
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Adaptability
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Output

Output Power Capacity
800 Watts / 1000 VA
Max Configurable Power
800 Watts / 1000 VA
Nominal Output Voltage
230V
Output Voltage Distortion
Less than 5%
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Topology
Line Interactive
Waveform Type
Sine wave
Output Connections
(8) IEC 320 C13 IEC 320 C13
(2) IEC Jumpers  

Input

Nominal Input Voltage
230V
Input Frequency
50/60 Hz +/- 3 Hz (auto sensing)
Input Connections
IEC-320 C14  
Cord Length
1.83 meters
Input voltage range for main operations
160 - 286V
Input voltage adjustable range for mains operation
151 - 302V

Batteries & Runtime

Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
3 hour(s)
Replacement Battery
RBC™ Quantity
1
DC Overcurrent Protection
60A
Runtime Graph
Curve Part Number(s)
A SMX1000I
B SMX1000I 
+ (1)SMX48RMBP2U
C SMX1000I 
+ (2)SMX48RMBP2U
D SMX1000I 
+ (3)SMX48RMBP2U
E SMX1000I 
+ (4)SMX48RMBP2U
Hover over the line on the graph above to view the runtime at any desired load
Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output.

Energy Use/Efficiency

Load Efficiency
25% 94.7%
50% 97.1%
75% 97.8%
100% 98.2%
Hover over the line on the graph above to view the efficiency at any desired load
Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced PF = 0.8 output.

Communications & Management

Interface Port(s)
SmartSlot, USB
Available SmartSlot™ Interface Quantity
1
Control panel
Multi-function LCD status and control console
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Emergency Power Off (EPO)
Yes

Surge Protection and Filtering

Surge energy rating
600 Joules
Filtering
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449

Physical

Support data are not available.

To submit your review please login first
Report Product Error Please select the product description error on the website:
Not readable? Change text.
CAPTCHA (Please enter the Code Above)
Calculate Shipping Method Cost
Suburb:
Post Code:
Calculate