The Online S Series UPS is ideal for servers, networking equipment, workstations and other mission-critical applications which require Pure Sine Ware power protection. Featuring Online Double Conversion design and Zero Transfer Time, it can provide consistent and seamless Pure Sine Wave power to critical loads. An optional SNMP/HTTP Remote Management Capability enables remote management and control of the system through standard web browser. The included PowerPanel® Business Edition management software provides corporate servers and critical workstations comprehensive network power management including unattended-shutdown, event logging, reporting, and notifications.
Features & Benefits:
Pure Sinewave Output
Online (Double Conversion) UPS Topology
High Output Power Factor (0.9)
Available with Up to 4 Units in Parallel
Tower Form Factor
EMI, RFI, Surge and Lightning Spike Protection
Phone/Fax/Modem/DSL/Network Protection
Auto-Restart/Auto-Charge
Emergency Power Off (EPO) Port
Multifunction LCD Readout
USB & Serial Connectivity Port
Smart Fan Speed Control By Load Level
Economy Mode setting
Smart Battery Management(SBM)
Generator Mode setting
SNMP/HTTP Remote Management Capability (Optional)
PowerPanel® Business Edition Software
Model | OLS10000E |
Capacity(VA/W) | 10000VA / 9000W |
Typology | Online (Double Conversion) |
Energy-Saving Technology | Yes, ECO Mode Efficiency > 96% |
Input | |
Input Type | Terminal Block |
Frequency Range | 45~65Hz |
Output | |
UPS Outlets (Numbers) | Terminal Block |
On Battery Output Voltage | Pure Sine Wave at 208, 220, 230, 240 Vac (Configurable) |
On Battery Output Voltage Distortion (@Nominal Battery Voltage) | < 2%(Linear Load), <5%(Non-Linear Load) |
On Battery Output Frequency | 50 Hz / 60 Hz (Auto-Sensing or Configurable) ± 0.5% |
Transfer Time (Typical) | 0ms |
Overload Protection |
Line Mode: 10 minutes minimum,then transfer to bypass @105%<Load≤125%; 1 minute minimum,then transfer to bypass @125<Load≤150% ; 10 second minimum then transfer to bypass @Load>150%; 1 second minimum then transfer to bypass@Load>170%; Battery Mode: 2 minutes minimum,then shutdown @105%<Load≤125%; 30 sec minimum,then shutdown @125<Load≤150% ; 1 second minimum then shutdown @Load>150% |
Short Circuit Protection | UPS Output Cut off Immediately or Circuit Breaker Protection |
Surge Protection and Filtering | |
Surge Protection | Yes |
DSL/Phone/Fax/Modem protection | No |
Physical | |
Dimensions(H x W x D)(mm) | 708 x 260 x 550 |
Weight(kg) | 86 |
Battery | |
Sealed Maintenance Free Lead Acid Battery | (20) 12V / 9AH |
Typical Recharge Time | 7 Hours |
Runtimes | |
Half load-Full load (mins) | 11/4 |
Status Indication | |
Indicators | Power On, Line Mode, Battery Mode, Bypass Mode, ECO Mode,C/F Mode, Fault, Replace Battery |
Audible Alarms | Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery |
Communication | |
Power Management Software | PowerPanel® Business Edition |
Management | |
Self-Test | Yes |
Auto-Charge/Auto-Restart | Yes |
Auto-Overload Recovery | Yes |
Cold Start(DC Start) | Yes |
Connectivity Ports | (1) Serial Port (RS232), (1) USB Port, (1) EPO/ROO |
SNMP/HTTP Capable | Optional |
Support data are not available.