BR1500GIFeatures

APC Power-Saving Back-UPS Pro 1500, 230V

High Performance Computer and Electronics UPS for Premium Power Protection

Includes : CD with software , Qty 1- Detachable IEC Power Cord , Telephone Cable , USB cable , User Manual , Warranty card

  • Adjustable voltage sensitivity

    Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

  • Adjustable voltage-transfer points

    Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

  • Audible alarms

    Provides notification of changing utility power and UPS power conditions

  • Automatic self-test

    Periodic battery self-test ensures early detection of a battery that needs to be replaced.

  • Battery failure notification

    Provides early-warning fault analysis on batteries enabling timely preventive maintenance

  • Battery replacement without tools

    Enables fast battery replacement, lowering Mean Time to Repair (MTTR).

  • Battery-protected and surge-only outlets

    Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

  • Boost and Trim Automatic Voltage Regulation (AVR)

    Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.

  • Building Wiring Fault Indicator

    This LED informs users of potentially dangerous wiring problems in the wall circuit.

  • Cold-start capable

    Provides temporary battery power when the utility power is out.

  • Dataline surge protection

    Provides protection of connected equipment from power surges on the data lines.

  • Disconnected battery notification

    Warns when a battery is not available to provide backup power.

  • Extendable Run Time

    Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.

  • Green mode

    Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

  • Hot-swappable batteries

    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

  • Intelligent battery management

    Maximizes battery performance, life, and reliability through intelligent, precision charging.

  • LCD graphics display

    Text and mimic diagrams that display modes of operation, system parameters and alarms.

  • Power-saving outlets

    Automatically cuts power to idle equipment to conserve electricity.

  • Resettable circuit breaker

    Easy recovery from overloads; no need to replace a fuse.

  • Safety-agency approved

    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

  • Serial connectivity

    Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.

  • Telephone dataline surge protection

    Provides protection of connected equipment from power surges traveling on telephone lines.

  • Transformer-block spaced outlets

    Protect equipment with input transformer blocks without blocking access to other receptacles.

  • USB connectivity

    Provides management of the UPS via a USB port (not available on all models).

  • User-replaceable batteries

    Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Back-UPS ProFeatures & Benefits

Manageability

  • Audible alarms

    Provides notification of changing utility power and UPS power conditions

  • USB connection

    Use your PC to access additional power protection and management features for your UPS via a USB Port.

  • LCD Status Display

    Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

  • Disconnected battery notification

    Warns when a battery is not available to provide backup power.

Safety

  • Safety-agency approved

    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Marketing Features

  • Battery-protected and surge-only outlets

    Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

  • Boost Automatic Voltage Regulation (AVR)

    Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

  • LCD Status Display

    Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

  • Green mode

    Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

  • Energy Management Function

    Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.

Protection

  • Dataline surge protection

    Provides protection of connected equipment from power surges on the data lines.

  • Battery and surge protected outlets

    Back up and protect your hardware and data during power outages, surges and spikes.

  • Surge only outlets

    Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Availability

  • Automatic self-test

    Periodic battery self-test ensures early detection of a battery that needs to be replaced.

  • Green mode

    Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

  • Transformer-block spaced outlets

    Protect equipment with input transformer blocks without blocking access to other receptacles.

  • Boost and Trim Automatic Voltage Regulation (AVR)

    Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

  • Cold-start capable

    Provides temporary battery power when the utility power is out.

  • Energy Management Function

    Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.

  • Battery failure notification

    Provides early-warning fault analysis on batteries enabling timely preventive maintenance

  • Intelligent battery management

    Maximizes battery performance, life, and reliability through intelligent, precision charging.

  • Customizable voltage sensitivity

    Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.

  • Customizable voltage-transfer points

    Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.

Serviceability

  • Resettable circuit breaker

    Easy recovery from overloads; no need to replace a fuse.

  • Simple battery replacement

    Increases UPS availability by allowing quick, easy battery replacement.

Product Distribution

Output

  • Output power capacity

    865Watts / 1.5 kVA

  • Max Configurable Power (Watts)

    865Watts / 1.5 kVA

  • Nominal Output Voltage

    230V

  • Output Frequency (sync to mains)

    50/60Hz +/- 3 Hz

  • Load Crest Factor

    3 : 1

  • Topology

    Line Interactive

  • Waveform type

    Stepped approximation to a sinewave

  • Output Connections

    (5) IEC 320 C13 (Battery Backup)

    (2) IEC Jumpers (Battery Backup)

    (5) IEC 320 C13 (selector_surgetitle)

  • Transfer Time

    10ms typical : 12ms maximum

Input

  • Nominal Input Voltage

    230V

  • Input frequency

    50/60 Hz +/- 3 Hz (auto sensing)

  • Input Connections

    IEC-320 C14

  • Input voltage range for main operations

    176 - 294V

  • Input voltage adjustable range for mains operation

    156 - 300V

  • Number of Power Cords

    1

Batteries & Runtime

Communications & Management

  • Interface Port(s)

    Optional Simple Signalling RS232 cable , USB

  • Control panel

    Multi-function LCD status and control console

  • Audible Alarm

    Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

  • Surge energy rating

    441Joules

  • Data Line Protection

    Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector)

  • Filtering

    Full time multi-pole noise filtering :10% of IEEE surge let-thgouh : zero clamping response time: instantaneous

Physical

  • Maximum Height

    301mm , 30.1cm

  • Maximum Width

    112mm , 11.2cm

  • Maximum Depth

    380mm , 38.0cm

  • Net Weight

    12.7kg

  • Shipping weight

    14.3kg

  • Shipping Height

    387mm , 38.7cm

  • Shipping Width

    238mm , 23.8cm

  • Shipping Depth

    488mm , 48.8cm

  • Color

    Black

  • Master Carton Units

    1.0

  • Units per Pallet

    20.0

  • SCC Codes

    1073130426874 8

Environmental

  • Operating Environment

    0 - 40 °C

  • Operating Relative Humidity

    0 - 95 %

  • Operating Elevation

    0-9000meters

  • Storage Temperature

    -15 - 45 °C

  • Storage Relative Humidity

    0 - 95 %

  • Storage Elevation

    0-15000meters

  • Audible noise at 1 meter from surface of unit

    45.0dBA

Conformance

  • Approvals

    A-tick, C-tick, CE, ENERGY STAR (EU), GOST, GS Mark, Telepermit, TUV

  • Equipment protection policy

    Lifetime : 200000 AUD, Lifetime : 150000 Euros, Lifetime : 75000 GBP

  • Standard warranty

    2 years repair or replace, 3 years repair or replace for European Union countries

Support data are not available.